Adobe Flash Professional CS3 Manual do Utilizador Página 136

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 135
FLASH CS3
User Guide
130
Files don’t appear in projects behind firewalls
Version Cue uses HTTP (Hypertext Transfer Protocol) and SOAP (Simple Object Access Protocol) to communicate
between Version Cue Servers and Adobe Creative Suite components. Rarely, older firewall software may not handle
SOAP interactions properly. If you see folders but not files in your Version Cue projects, try disabling your proxy
server. If disabling the proxy server resolves the problem, you may need to update your firewall.
Disconnecting from projects with files checked out
If you have local project files with the Checked Out By Me status, you cant disconnect from a project until you check
in a version of those files. If you cant check in a version of the files because the Version Cue Server is unavailable,
there are two ways to proceed. You can wait until the server is available, synchronize the files, and then disconnect
fromtheproject.Or,youcandeletethelocalprojectfilesfolderfromyourharddriveandthendisconnectfromthe
project when the server is available. (Other users who access the project will still see the files marked as Checked
Out. Users can save their own versions, or a user with Administrator privileges can reset locks on the project, which
changes the status of the files to Synchronized.)
Unable to see thumbnails for InDesign files in the Adobe dialog box or Bridge
If you don’t see thumbnails for InDesign files in the Adobe dialog box or in Bridge, select Always Save Preview
Images With Documents in either the File Handling preferences or the Save As dialog box in InDesign.
Unable to migrate from Version Cue CS2 to Version Cue CS3 on Intel-based Macintosh computers
To migrate projects from Version Cue CS2 to Version Cue CS3 on an Intel-based Macintosh computer, first back up
the project in the Version Cue CS2 Advanced Administration utility on a PowerPC-based Macintosh computer. (For
instructions, see Version Cue CS2 Help.) Then, transfer the project from the PowerPC-based Macintosh to the
project backup directory on the Intel-based Macintosh computer, restart the server, and restore the project in
Version Cue CS3 (see “Back up and restore projects” on page 121).
Note: You cannot migrate Version Cue CS2 server backups to a Version Cue CS3 Server. You can, however, migrate
Version Cue CS2 projects to a Version Cue CS3 Server. See “Migrate projects to the Version Cue 3.0 Server” on page 94
Unable to connect to the Version Cue CS3 Server
Try any of the following:
Make sure that your network connection is functioning properly.
If you’re trying to connect to the server from Acrobat 8 or from a Version Cue-enabled Adobe Creative Suite 2
component, make sure that you havent enabled SSL for the server. In addition, Acrobat 8 and Adobe Creative
Suite 2 components cant connect to Version Cue CS3 Servers installed on the same computer (that is, a local
Version Cue CS3 Server).
Try to connect to the server from a different Version Cue-enabled Creative Suite component.
Temporarily disable firewalls or proxies.
Restart the server (see “Shut down or restart the Version Cue Server” on page 95).
Consulttheserverlogfilefordetailsthatmayindicatethecauseoftheproblem.Youcanaccessthelogfilefrom
the Advanced tab of Version Cue Server Administration (see “Advanced Version Cue Server Administration
tasks” on page 123).
Vista de página 135